GÜRClimate Plus
Semi-Automatic Air-Conditioning
Semi-automatic ventilation and cooling system is used in poultry house systems up to a capacity of 60.000 birds.
The system comprises of a fan, pad, pump, water tank and an automation panel which controls them all in accordance with the climatic conditions in the region. The number of fans and pads required is determined by the number of the birds in the building. Fans and pads are positioned according to the condition of the building. In the system, there is a flap and, when deemed necessary, a damper in the building for the adjustment of air intake. In the system, the temperature in the poultry house is transferred to the automation panel by means of thermometers positioned at different places in the poultry house. In accordance with the incoming data, the automation panel controls the fans to discharge the polluted air from the poultry house and controls the flaps and dampers to allow an adequate amount of fresh air to come in. In the semi-automatic system, the flaps are manually controlled. Depending on the season, only ventilation or ventilation-cooling is provided. Cooling is provided by the use of the pads. The fresh air taken in from the outside of the poultry house is passed through the pads while being transferred to the interior. Thanks to the pipes on the pads, water is delivered into the pads. The air is laden with the moisture in the water while it passes through the pads and cools down and enters the poultry house in a cooled manner. Cold air is directed to the roof by means of the flaps. As the cold air is heavy, it moves towards the lower tiers of the cage and enters in. Thus, fresh and cool air is delivered to all the parts of the poultry house. This is called the sprinkling system. There is an audible and lighted alarm system for any problems which may occur in the ventilation system.

Specifications.
- It reads and controls the temperature values of the two parts (front and back) of the poultry house.
- It provides maximum and minimum ventilation.
- In-house temperature values may be monitored on the screen.
- Alarm is activated in case of fan or pad failures, power outage and exceeding maximum or minimum temperature values, giving both an audible and lighted warning.
- Semi-automatic ventilation and cooling system achieves the best desired values in the poultry house and provides a homogenous air-conditioning.
Ventilation Fans:
- A design making it possible to replace belt easily
- Lower energy consumption
- Lower noise level
- Galvanised sheet flap
- Holes for post-cleaning water discharge
Technical Specifications of Fan
- Air Capacity
38.400 m3 / h @ 0 pa
36.700 m3 / h @ 10 pa
- Revolution:
447 rev/min
- Motor Power:
1,5 HP
- Dimensions:
Width : 1.400 mm
Length : 1.400 mm
Depth : 420 mm
- Voltage:
220 V – 380 V
|